YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage 1.Applications -These cables are used for electric
Basic Info.
Model NO. | low voltage cable |
Wire Core Material | Bare Copper Wire |
Certification | ISO, CCC, CE, RoHS, VDE |
Model | VV, Yjv... |
Brand | Chang Qing Teng |
Insulation | XLPE/PVC/PE/PUR |
Conductor | Stranded/Solid/Flexible Copper/Aluminum Conductor |
Shield | Copper Wire Screen(Cws), Aluminium Wire Screen(Aws |
Armoured | Steel Tape Armoured (Sta) or Steel Wire Armoured ( |
Aplication | Electric, House Wire, Building Wire... |
Cross Section Area/Measure | 3.5/4/6/10/16/25/35/50/70/95/120/150/185/240/300/4 |
Standard | IEC 60502-1, BS 7870-6, BS 6622, BS 7835, GB 5023- |
Number of Cores | Single/2/3/4/5/6/7/8/10/16 Core... |
Product Name | Low Voltage Cable/ PVC Cable/ XLPE Cable/ Armoured |
Transport Package | Non-Fumigation Wooden Drum, Iron-Wooden Drum. |
Specification | 350x160x270,800x350x550,1000x500x600,1200x500x900. |
Trademark | Luxing |
Origin | Shandong |
HS Code | 8544492100 |
Production Capacity | 500000meters/Year |
Product Description
YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
1.Applications
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors,in cable ducts, underground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
2.Construction
-ConductorsThe conductors shall be either of Class 1 or Class 2 of plain accordance with IEC 60228.-InsulationPVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
-Assembly / Inner CoveringThe inner coverings may be extruded or lapped.
-ArmourAluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
-Outer SheathOuter sheath shall be of extruded PVC as per IEC 60502-1, Polyethylene, Halogen free compound.Polychloroprene, chlorosulfonated polyethylene or similar polymers.
-Fire Performance of Cable SheathsCables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Parameters
Single core(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
1x4 | 2.3 | 1 | 1.4 | 7.1 | ||
1x6 | 2.8 | 1 | 1.4 | 7.6 | ||
1x10 | 3.6 | 1 | 1.4 | 8.4 | ||
1x16 | 4.5 | 1 | 1.4 | 9.3 | ||
1x25 | 5.6 | 1.2 | 1.4 | 10.8 | ||
1x35 | 6.7 | 1.2 | 1.4 | 11.9 | ||
1x50 | 8 | 1.4 | 1.4 | 13.6 | ||
1x70 | 9.4 | 1.4 | 1.4 | 15.1 | ||
1x95 | 11 | 1.6 | 1.5 | 17.2 | ||
1x120 | 12.4 | 1.6 | 1.5 | 18.7 | ||
1x150 | 13.8 | 1.8 | 1.6 | 20.6 | ||
1x185 | 15.3 | 2 | 1.7 | 22.7 | ||
1x240 | 17.5 | 2.2 | 1.8 | 25.4 | ||
1x300 | 19.5 | 2.4 | 1.9 | 28.0 | ||
1x400 | 22.6 | 2.6 | 2.0 | 31.7 | ||
1x500 | 25.2 | 2.8 | 2.1 | 35.0 | ||
1x630 | 28.3 | 2.8 | 2.2 | 38.3 |
Two cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
2x1.5 | 1.4 | 0.8 | 1.8 | 9.6 | ||
2x2.5 | 1.8 | 0.8 | 1.8 | 10.4 | ||
2x4 | 2.3 | 1 | 1.8 | 12.2 | ||
2x6 | 2.8 | 1 | 1.8 | 13.2 | ||
2x10 | 3.6 | 1 | 1.8 | 14.8 | ||
2x16 | 4.5 | 1 | 1.8 | 16.6 | ||
2x25 | 5.6 | 1.2 | 1.8 | 19.6 | ||
2x35 | 6.7 | 1.2 | 1.8 | 21.8 | ||
2x50 | 8 | 1.4 | 1.8 | 25.2 | ||
2x70 | 9.4 | 1.4 | 1.9 | 28.1 | ||
2x95 | 11 | 1.6 | 2.0 | 32.4 | ||
2x120 | 12.4 | 1.6 | 2.1 | 35.4 | ||
2x150 | 13.8 | 1.8 | 2.2 | 39.2 | ||
2x185 | 15.3 | 2 | 2.4 | 43.3 | ||
2x240 | 17.5 | 2.2 | 2.5 | 48.9 | ||
2x300 | 19.5 | 2.4 | 2.7 | 54.0 | ||
2x400 | 22.6 | 2.6 | 2.9 | 61.5 |
Three cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
3x1.5 | 1.4 | 0.8 | 1.8 | 10.1 | ||
3x2.5 | 1.8 | 0.8 | 1.8 | 10.9 | ||
3x4 | 2.3 | 1 | 1.8 | 12.9 | ||
3x6 | 2.8 | 1 | 1.8 | 13.9 | ||
3x10 | 3.6 | 1 | 1.8 | 15.7 | ||
3x16 | 4.5 | 1 | 1.8 | 17.6 | ||
3x25 | 5.6 | 1.2 | 1.8 | 20.8 | ||
3x35 | 6.7 | 1.2 | 1.8 | 23.2 | ||
3x50 | 8 | 1.4 | 1.8 | 26.9 | ||
3x70 | 9.4 | 1.4 | 1.9 | 30.1 | ||
3x95 | 11 | 1.6 | 2.1 | 34.7 | ||
3x120 | 12.4 | 1.6 | 2.2 | 38.0 | ||
3x150 | 13.8 | 1.8 | 2.3 | 42.1 | ||
3x185 | 15.3 | 2 | 2.5 | 46.5 | ||
3x240 | 17.5 | 2.2 | 2.7 | 52.5 | ||
3x300 | 19.5 | 2.4 | 2.8 | 58.0 | ||
3x400 | 22.6 | 2.6 | 3.1 | 66.1 |
Three cores+1(unarmoured) | ||||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||||
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm | ||
3x 16/10 | 4.5 | 3.6 | 1 | 1 | 1.8 | 19.0 | ||
3x 25/16 | 5.6 | 4.5 | 1.2 | 1 | 1.8 | 22.6 | ||
3x 35/16 | 6.7 | 4.5 | 1.2 | 1 | 1.8 | 25.3 | ||
3x 50/25 | 8.0 | 5.6 | 1.4 | 1.2 | 1.9 | 29.6 | ||
3x 70/35 | 9.4 | 6.7 | 1.4 | 1.2 | 2.0 | 33.2 | ||
3x 95/50 | 11.0 | 8.0 | 1.6 | 1.4 | 2.2 | 38.4 | ||
3x120/70 | 12.4 | 9.4 | 1.6 | 1.4 | 2.3 | 42.0 | ||
3x150/70 | 13.8 | 9.4 | 1.8 | 1.4 | 2.5 | 46.6 | ||
3x185/95 | 15.3 | 11.0 | 2 | 1.6 | 2.6 | 51.6 | ||
3x240/120 | 17.5 | 12.4 | 2.2 | 1.6 | 2.9 | 58.3 | ||
3x300/150 | 19.5 | 13.8 | 2.4 | 1.8 | 3.1 | 64.5 | ||
3x400/185 | 22.6 | 15.3 | 2.6 | 2 | 3.3 | 73 |
Four cores(unarmored) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
4x1.5 | 1.4 | 0.8 | 1.8 | 10.8 | ||
4x2.5 | 1.8 | 0.8 | 1.8 | 11.8 | ||
4x4 | 2.3 | 1 | 1.8 | 14.0 | ||
4x6 | 2.8 | 1 | 1.8 | 15.2 | ||
4x10 | 3.6 | 1 | 1.8 | 17.1 | ||
4x16 | 4.5 | 1 | 1.8 | 19.3 | ||
4x25 | 5.6 | 1.2 | 1.8 | 22.9 | ||
4x35 | 6.7 | 1.2 | 1.8 | 25.6 | ||
4x50 | 8 | 1.4 | 1.9 | 29.9 | ||
4x70 | 9.4 | 1.4 | 2.0 | 33.5 | ||
4x95 | 11 | 1.6 | 2.2 | 38.7 | ||
4x120 | 12.4 | 1.6 | 2.3 | 42.3 | ||
4x150 | 13.8 | 1.8 | 2.5 | 46.9 | ||
4x185 | 15.3 | 2 | 2.6 | 51.9 | ||
4x240 | 17.5 | 2.2 | 2.9 | 58.6 | ||
4x300 | 19.5 | 2.4 | 3.1 | 64.8 | ||
4x400 | 22.6 | 2.6 | 3.3 | 73.8 |
Multi-cores(unarmoured) | ||||||
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | mm | mm | mm | mm | ||
5x1.5 | 1.4 | 0.8 | 1.8 | 11.7 | ||
7x1.5 | 1.4 | 0.8 | 1.8 | 12.6 | ||
10x1.5 | 1.4 | 0.8 | 1.8 | 15.6 | ||
12x1.5 | 1.4 | 0.8 | 1.8 | 16.1 | ||
14x1.5 | 1.4 | 0.8 | 1.8 | 16.8 | ||
19x1.5 | 1.4 | 0.8 | 1.8 | 18.6 | ||
21x1.5 | 1.4 | 0.8 | 1.8 | 19.5 | ||
24x1.5 | 1.4 | 0.8 | 1.8 | 21.6 | ||
30x1.5 | 1.4 | 0.8 | 1.8 | 22.8 | ||
40x1.5 | 1.4 | 0.8 | 1.8 | 27.7 | ||
48x1.5 | 1.4 | 0.8 | 1.9 | 28.2 | ||
61x1.5 | 1.4 | 0.8 | 1.9 | 30.9 | ||
5x2.5 | 1.8 | 0.8 | 1.8 | 12.8 | ||
7x2.5 | 1.8 | 0.8 | 1.8 | 13.8 | ||
10x2.5 | 1.8 | 0.8 | 1.8 | 17.2 | ||
12x2.5 | 1.8 | 0.8 | 1.8 | 17.7 | ||
14x2.5 | 1.8 | 0.8 | 1.8 | 18.6 | ||
19x2.5 | 1.8 | 0.8 | 1.8 | 20.6 | ||
21x2.5 | 1.8 | 0.8 | 1.8 | 21.6 | ||
24x2.5 | 1.8 | 0.8 | 1.8 | 24.0 | ||
30x2.5 | 1.8 | 0.8 | 1.8 | 25.4 | ||
40x2.5 | 1.8 | 0.8 | 2.0 | 31.1 | ||
48x2.5 | 1.8 | 0.8 | 2.0 | 31.7 | ||
61x2.5 | 1.8 | 0.8 | 2.1 | 34.7 |